skip to main content
Call Us Email Us

Technical Support

CE marked CE marked
Class I rated Class I rated - Basic insulation and all exposed conductive 
parts connected to an earth terminal.
Class II rated Class II rated - Basic and supplementary insulation in 
accordance with BS EN60598. No provision for an 
earth connection.
ENEC mark The control gear in this fitting carries the ENEC mark
IK08 Protected against 5 joules impact.
Equivalent to impact of 1.7kg mass dropped from 300mm above impacted surface.
IK09 Protected against 10 joules impact.
Equivalent to impact of 5kg mass dropped from 200mm above impacted surface.
IK10 Protected against 20 joules impact.
Equivalent to impact of 5kg mass dropped from 400mm above impacted surface.
IP20 Protection against solids larger than 12.5mm. No protection against liquids.
IP40 Protection against solids larger than 1mm.No protection against liquids.
IP44 Protection against solids larger than 1mm. Protection against splashed liquids.
IP54 Limited protection against dust ingress (no harmful deposit). Protection against splashed liquids.
IP55 Limited protection against dust ingress (no harmful deposit). Protected against low pressure water jets from any direction (Limited ingress permitted).
IP65 Totally protected against dust ingress. Protected against low pressure water jets from any direction (Limited ingress permitted).
IP66 Totally protected against dust ingress. Protected against high pressure water jets from any direction (Limited ingress permitted).
IP67 Totally protected against dust ingress. Protected against short periods of immersion in water.
IP68 Totally protected against dust ingress. Protected against long, durable periods of immersion in water.
sym-firerated This fitting has been tested     
and found suitable for use in solid timber and I-beam ceilings fire rated to 30, 60 and 90 minutes to BS476.
sym_5yr_unlimited This fitting is supplied with a 5-year unlimited 
hours warranty.
This fitting is supplied with a 7-year unlimited 
hours warranty.
sym_5yr_lithium This fitting is certified for use in wood, paper and textile processing plants. This symbol confirms that the outer surfaces of the luminaire on which highly flammable substances such as dust or fibres may gather do not exceed the temperature limits specified in EN 60598-2-24.
L70 The L value (70 in this case) is the expected average lumen output of the fitting, expressed as a % of its initial output, at the end of its rated life. The lower value (50,000 in this case) is the rated life of the product in hours
The L value (80 in this case) is the expected average lumen output of the fitting, expressed as a % of its initial output, at the end of its rated life. The lower value (100,000 in this case) is the rated life of the product in hours
sdcm3 When new, the colour of the light emitted by all the fittings in any one batch will fall within 3 standard deviations of each other.
sdcm5 When new, the colour of the light emitted by all the fittings in any one batch will fall within 5 standard deviations of each other.
The thermoplastic diffuser material in this fitting has been tested and found to have the characteristics required for TP(a) rating.
The thermoplastic diffuser material in this fitting has been tested and found to have the characteristics required for TP(b) rating.
1_10v This fitting can be controlled with a 1-10V (analogue) control signal
This fitting is dimmable with suitable mains (phase cutting) dimmers.
lithium_seal Emergency versions of this product are available. They are fitted with lithium iron phosphate (LiFePO4) batteries.
HubSense smart wireless control options are 
available.
Environmental Product Declaration. An EPD, evaluated in line with ISO 14025:2006
ICEL is the Industry Committee for Emergency Lighting, part of the Lighting Industry Association (LIA). ICEL Endorsed products have been independently tested to the relevant standards and the test reports assessed and checked by ICEL.


Back to Technical Support